If the oven display is black, no lights on the display, refer to the suggestions below for step by step instructions.

 Some oven models with Omega, Vision VCU and Hexagon electronics are equipped with a power-saving mode to deactivate the display in standby mode.

Omega electronics:

Fig 1. Example of AEG aesthetics.

Fig 2. Example of Electrolux aesthetics.

 

The Omega electronics have a power-saving mode to deactivate the display (dark display, in standby only).

  • Simultaneously pressing the “up”  button and the button with the “clock” symbol makes the display go dark (in standby mode only).
  • If the display is dark, press the “UP”  button and the “clock”  button. The display will show the time in standby mode again.
Note: Be careful with the Electrolux look, where the two buttons that are used to activate the function are very close together and can sometimes be activated accidentally.

Note: If there are problems with a dark display in Vision VCU, you must disconnect the equipment from the mains and then reconnect it to reset any electronic problems before replacing any components (this is due to a known problem in Vision VCU where a power failure can sometimes also deactivate the display).

 Vision VCU electronics:


Fig 3.

The VCU electronics have a power-saving mode to deactivate the display (dark display, in standby only).

  • The function can be activated/deactivated from the BASIC SETTINGS menu and then TIME INDICATION.

Note: If there are problems with a dark display in Vision VCU, you must disconnect the equipment from the mains and then reconnect it to reset any electronic problems before replacing any components (this is due to a known problem in Vision VCU where a power failure can sometimes also deactivate the display).

 Hexagon electronics:


Fig 4.

Some versions of the Hexagon electronics have a power-saving mode to deactivate the display (dark display, in standby only).

  • To deactivate (on a display in standby) or reactivate the function (display switched off in standby), press the  and  buttons simultaneously for two seconds.

Note: In some versions of the Omega, Vision VCU and Hexagon interfaces, the function to deactivate the display (dark display)  is not permitted by the configuration software. When there are problems with electronic models with the display switched off, you must disconnect the equipment from the mains and then reconnect it to reset any electronic problems before replacing any components (this is sometimes also due to a loss of power for a certain period of time).